Fanuc write protect parameters

 

Fanuc write protect parameters. When parameter 3202, Bit 0 is set to 1: – Program numbers in the range of O8000 through O8999 cannot be edited or deleted. if you power off, the machine will re-set PWE to 0. This is it’s new zero position. PARAMETER MANUAL B–63690EN * FANUC Series 0 i/16/18/20/21 PROGRAMMING MANUAL (Macro Compiler/Macro Executor) B–61803E–1. Carfully overwrite the whole number (bit 1 is the farthest to the right, bit 8 is fathest to the left) Jul 30, 2021 · Unable to Enable parameter write. Jul 27, 2018 · Re: write protect in macro input. After the changes, It write Locked Parameters Jan 31, 2024 · I've changed parameter write back to 0 and there dose not seem to any key related to "memory protect key". Mar 30, 2012 · F1 (Inst) -> LOCK PREG. Write Protect Issue - Fanuc Robodrill D21MiB5adv PLUS with 31i-B5 Plus control. I change the 2201 NE9 Bit 0 to unlock the 9000 series parameters. 07-19-2018, 01:23 PM #2. 10-25-2020, 01:50 PM #26. Page down once (you should see PWE Enable) change to 1. Oct 18, 2016 · Press SELECT, highlight the TP program with the cursor, press F2-DETAIL, and set Write Protect: Off. 3402 G Codes that are Active When The machine is Turned On. 3299#0), and the switch of enable or disable setting of input parameter is set by the signal KEYP. If you simultaneously press the RESET and DELETE keys at powerup, you'll clear all SRAM memory (part programs, parameters, offsets, PMC Parameters, Tool Life data, CAP data, etc). I feel like the answer is obvious but I can't seem to resolve it. It always refers me to contact the dealer of the machine. INPUTTING AND OUTPUTTING PARAMETERS THROUGH B–63610EN/01 THE READER/PUNCHER INTERFACE 3. All Fanuc 6M and 6M-B controls had two toggle switches on two opposite corners of the board. If I understand correctly your just trying to name the variable, I am not familiar with the Fanuc Oi-TF control but I do know that in other Fanuc controls you can set your data like this: in MDI mode you would write SETVN500 [xxxxx]; then hit cycle start. Hope that helps you out. By cnc programmif hindi and english-~-~~-~~~-~~-~-This Video and channel Windows XP) In case of Windows XP, type in "ipconfig" then click Enter. The manual says to go to the settings screen, enter 8000, press the input number Fanuc > FANUC 15T Write Protect Door Interlock override ? 18i-TB. Jan 8, 2013 · 1. Search" . 5) ENTER 1 AND PRESS 'INPUT' SOFTWARE KEY. This does not happen. IF the ladder is not then you won't. It's labeled "PRM", or something like that. 3----> 1 fanuc 31i controller Sep 9, 2015 · Re: Tool Offset and Work Offset Locking on Fanuc OiMD. You can protect your cnc parameter, offset, ladder using this method. PWE=1 IS SPECIFIED AND. To go there, press OFS/SET. WRITE PROTECTED PARAMETERS? can anyone tell me a way around this or what i'm supposed to do to change these parameters? it just keeps saying that they are write protected? 100. 2) PRESS SOFTWARE KEY 'SETTING' TO SELECT SETTING SCREEEN. 1 Y-245. This happened after i changed a parameter 3290 thinking it would change Key3 so Jun 12, 2019 · HiNeed some help, I'm trying to copy an program from the Data server to CNC memory on Fanuc 31i model B control. Page 12 3. The switch of enable or disable of this function is set by the parameter PKY(No. Modifying FANUC date , always keep saying Write protect. That's to put the bubble memory into "free mode", and you don't want to do that. They will need to be set into the Ethernet parameters on the NC, later. About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright Jun 30, 2022 · Some more interesting parameters. The variable #0 always has a null value, and you can give any other variable a null value just by assigning #0 to it. First, I change the PWE 8000 parameters. 2 When the value of the password is not 0, the parameter screen does not display the password. ) or PLC (6400's par) or whatever to get to desired set of parameter numbers. Register the deleted program. 231 is issued. How do turn this off? Is there another way to change jog speed override? Thanks. Below are the most common used data carrier. NOW PARAMETERS CAN NOW BE SPECIFIED. and shows alert message again how Write-Protected . If not you may have to adjust the rapid parameter for the machine. Then through the ladder turn the write protects on and off, then add a good keyswitch for the input. With older controls like the 3, 5, and 6 series Fanuc controls (6MB for example), it is a physical switch. Conceal Shot; Review Canned Cycle By L and K; Background Edit Fanuc; Memory Card; Fanuc OT More Fun Than She Think; Fanuc Relative Position; Fanuc Parameters. Parameter write enabling on Fanuc OiT. If there was a parameter to protect the normal range programs it would not allow you to delete them or read them from a DNC network. you’d just need the key to get to the “deeper” shit. 0010= 10010001 9000 Protect on. Fanuc have two ways of putting on chamfers and rads and that’s where the confusion lies. Tool change macro is available for modifications, i can put all the coordinated inside the Dec 2, 2011 · hope this helps. This parame Re: Fanuc 180i MB - changing parameter 3202 bit "NE9". Parameter 3202 is an eight bit parameter with bits 0 and 4 used to inhibit program editing. 7. PWE is enabled. When a value other than zero is set in this parameter and this value differs. I want to edit macro variable input during write protect key is in OFF condition or removed from Fanuc Oi-TF model panel. When we subsequently call this G code the machine will use this position as it’s datum. Apr 12, 2005 · I talked to a fill in Fanuc expert this morning and he seconded what Tommy said. Dependant on the controller and if the tool change macro is available for modifiction if it s its easy to change. Press the function key “OFFSET SETTING”. I assume you can't run the machine when the key is in the unlock state? If so, change K4 bit 0 to 1 and you can run the machine with the key in any Sep 5, 2022 · This video explains who to disable or lock system button using parameter. Apr 25, 2010 · 1) PUT SCREEN IN MDI MODE OR E-STOP STATUS. If you have a parameter manual for the Oi control, look under the Marco programing section, it should e listed there. Press "SETTINGS" softkey twice to get "SETTING (SETTING)" screen. It remains with 0 . When tried to change the " PARAMETER WRITE : 0 " for " PARAMETER SCRIPT : 1 " It cannot changed . zero return 2. ***write down the current value***. 2----> 0 100. Edited once, last by ASIJordan ( Sep 28th 2019 ). That worked, I got the parameters changed and that fixed the other problem. 0010= 10000001 9000 Protect off. This switch allows you to enter the parameter setting mode. He also mentioned he thought that he thought there might be a parameter that would limit the amount of offset allowed. If the robot is almost a perfect L it will give the fault everytime. Hi, Press EMERGENCY STOP button. Jan 30, 2015 · Re: Fanuc 18i-MB parameter write protected leave PWE on 1 and DO NOT power off. Change Bit #0 from 0 to a 1. Trophies. 09-03-2010,10:11 PM #2. May 21, 2019 · The parameter-write-enable (pwe) switch. 6. 9000 to 9999. Fortunately in another post, someone explained the "Parameter" byte value one screen up. Feb 16, 2007 · Keep in mind that there are signals in the PMC that can be set to inhibit Work Offsets with PWE. Then at the write protect line, change it to true. Just wanted to give a suggestion. I have a 0i that requires me to use the edit write protect key to change the tool offsets. ex. Check G8. 3211, bit 4 (NE9) of parameter. I KEEP GETTING WRITE Sep 3, 2010 · Posts. So beware back em up ASAP. You can however protect programs from edit or deletion and they will be To set “PARAMETER WRITE=” to 1, press the ON:1 soft key, or alternatively enter 1, then press the [INPUT] soft key. Re: Fanuc 6m-B where is the write parameter or protection key parameter? The Fanuc 6M-B doesn't have a parameter to protect the parameter input, like the later models. That's fine, ignore that alarm and change your parameters and when you return PWE to 0 the alarm will be cleared. You’d still have to do the normal stuff, like toggle PWE. Programs 9000 to 9999 are used for things like probing, tool-change and all sorts of other important things. CHANNEL NO. Sep 4, 2013 · In my integrex, a simple parameter change by a service tech led to an extemely loud bang and destroyed a tool and toolholder, knocking 2 spindles out of alignment in the process. Let's try. But if your just looking to protect programs in the range of 0-7999 then PMIN, PMAX is the only way to go. Input Start and End number of the parameters that should be read. Hey I'm hoping to get some help with an issue I have created with one of our old machines. In my parameter list, it says that this value must be 00000010; according to the other post this would be for "decimal with write protect". I HAVE FOLLOWED THESE INSTRUCTIONS AND STILL Access to the I/O CHANNEL parameter is in the SETTINGS window, exactly where we enable the option of parameter editing. Press the soft key “SETTING”. And, you do not have to forget the PASSWD, which is not displayed on the screen. Aug 1, 2014 · I try to unlock the 9000 parameters on my Fanuc 10T. 5. The manual says to go to the settings screen, enter 8000, press the input number soft key and the paramater should display on the screen. Mar 10, 2023 · Unlock Programs Fanuc Parameter, first of all you’ll need to go to the setting screen and change the parameter write box to a 1. Instead, there's a toggle switch on one corner of the main PCB. (If the screen changes to an alarm message, press SETTING to return) Cursor down to TV Check. Changing CNC Parameters: Place the NC in MDI mode. 1 (1) Select the EDIT mode or set to Emergency stop. 0 press MEASURE and it says WRITE PROTECT. Jan 30, 2022 · Here’s an article on it if you want to use it. 16/18/21, 16i/18i/21i, 160i/180i/210i, 0/00/0-mate, 0i. #1. I have the machine completely back up again with the exception of uploading the stock 9000 programs from the disk. 05-21-2009, 12:05 AM #5. But : Before changes, when I try to modify 9109 parameters, it write Write Protect. After clicking [Query] you should see output similar to the following in the right pane: FIG 1: FanucParamReadGui: Read parameters 6710 - 6713. The system will respond with the IP-address Subnet Mask-address as well. Possibly, there is no way, at software level at least. Type in "8000" then press "INP-NO". Fanuc Parameter Write Switch; Clear MDI Screen Fanuc Parameter 3203; Decimal Point Fanuc Parameter 3401; GRAMME Code Alias Fanuc Parameter 6050; M Code Alias Fanuc Control 6080 Need Help! Write Protect Issue - Fanuc Robodrill D21MiB5adv PLUS with 31i-B5 Plus control. When I go to turn off write protection it does nothing. 3202#0 & #4 on 0i MB. It needs to be on to allow axis movement. Insert LOCK before the Position Registers you want to lock, insert UNLOCK when passed the Position Registers you want to lock. This parameter sets a password for protecting program Nos. 186. certain time is very unusual. 2 These will not alter until you do it. Just do as you’re told (oh and read this article) So in Parameter 3453 you can set bit #0 (CRD) to a 1 this allows what Fanuc call “Direct Drawing Inputs” to work. 1 Y -245. Advertisement. Sep 28, 2019 · 1. Need Help!-. Fanuc 10, 11, 12 and 15 Series Machine Parameters. 2) To set data consecutively, use EOB key. I've looked through various manuals and menus but cannot seem to find any options/variables that relate to MD: write protection. Move the cursor to “PARAMETER WRITE” . It's suposed to unlock all the parameters. To make any changes to the machine parameters you must enable Parameter Write Enable (PWE). Type1815 and press "No. However, to do anything, we must first enable parameter editing according to the procedure described HERE. However the machine really needs the diagnostic parameters to work. 6080-6089 Allows you to Call a 9000 series Program with An Jun 14, 2010 · Press "SETTINGS" softkey twice to get "SETTING (SETTING)" screen. Feb 19, 2018 · Re: Variable for reference position (G30) Originally Posted by mbservice. And 3202 bit 4 protects programs in Oct 22, 2020 · Re: Modifying FNUC date , always keep saying Write protect. Fanuc 15–MB Parameter Manual. EGO astonish if there is a memory protect that has to May 20, 2019 · You must reference you Fanuc Operators manual to find the related parameters. This is linked to the Keyword and Password set in 3210 and 3211. I can still edit programs, so it's not the key on the front panel. I manually entered all of the parameters because I bought the wrong pcmcia car . 1?64) Geometry offset value (Offset No. Sep 28th 2019. a_mostafa. The method to reset the password is not given. These bits can also be "locked" by specifying KEYWD (parameter 3211) and PASSWD (parameter 3210). It should be documented in the custom macro B section, near the description of permanent common variables. Like you can still have access to offsets and mdi screen, but lock out the parameters. When EGO try to copy from CNC memory to the Data server cannot problems at all. Alarm " SW000 PARAMETER ENABLE SWITCH ON " will appear. Jun 3, 2015 · I would STRONGLY suggest avoiding using password protection of parameters because WHEN (not if) that password gets forgotten, misplaced, "accidentally" changed, you're in for a world of hurt that only FANUC can fix. 3210 Password. DO NOT TOUCH the other toggle switch, called "BMU". From now on, parameters can be set. took this from the fanuc manual: Alarm 101-please clear memory: The power turned off while rewriting the memory by program edit operation. Turn on PWE (Parameter Write) make it a 1. Create an account or sign in to comment You need to be a member in order to leave a comment Nov 5, 2008 · That way you don't have to worry about a new program number you want to protect being in the range you specify or having to expand the range of protection. You must open the Fanuc control door and find the switch. I went to parameter D4044 to set the value to 1 but it says its "write protect". If this alarm has occurred, press <RESET> while pressing. Oct 11, 2008 · I have found thet I need to modify Parameter 8000 - PWE to 1 to clear the write protect but have been unable to do so. About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright Jan 10, 2013 · Also, you must be in MDI mode. Thanks Similar Threads: Fanuc 18T work offset measure help; Activating touch probe on Fanuc in measure Cycle Nov 4, 2017 · By using 3202 parameter || NE 8 for O 8000 & || NE 9 for O 9000 series. IS DISPLAYED. Sep 3, 2010 · can anyone tell me a way around this or what i'm supposed to do to change these parameters? it just keeps saying that they are write protected? 100. It is a toggle switch, and is commonly placed at the lower left corner of the Mar 27, 2017 · Fanuc 21-T programs are write protected. So, I hope that I am posting this correctly to hopefully get a. : Nov 2, 2005 · Param button. in X and – 145. If you successfuly set 8000 bit 0 (PWE) to 1, you'll get that alarm saying that the parameter write switch is on. Write down all of the numbers. Posts. I tried both $MCR and $SCR and I get Variable/ field write-protected. I would just leave the key in the machine, but I don't trust them to not accidentally change a Mar 15, 2018 · The Fanuc 6M-B doesn't have a parameter to protect the parameter input, like the later models. 3203 Clear MDI Screen. On the screen above if you programmed G0 G54 X0 Y0 the machine would move -75. Enter the correct axis number for the parameter to be queried (-1 = all axes, 0 = no axes, 1-n = axis number). I'm guessing they will be PMC parameters because that kind of write function only at a. Parameter number 8000 should appear on the screen. Jan 15, 2011 · 1792. I'm trying to locate the correct parameter to allow my setups to change tool offsets without the use of the key. 01-10-2013, 08:09 AM #3. there are parameters for that. ;Correct the program. Aug 19, 2014 · The Parameter total 100 , 101 are unable until correct since it lives " WRITE-PROTECTED". 1?99) Geometry offset value (Offset No. The controller is Fanuc 21i. One was marked "BMU", which is for the bubble memory, and the other is "PRM" or "PARM". Re: FANUC 20-M: Cannot write PMC data (Write protect) Of course I figured it out after asking twice. Oct 11, 2012 · Control Model. Set to 1 by pressing the "ON:1" softkey. On the 16 control May 21, 2009 · Protection is possible only for 8000 and 9000 series programs through parameter no. 0 in the ladder to see if it turns on. Press RESET to release alram 100. If you don't have a main board like this, then maybe you don't have a 6M-B like you think. Care must be taken in setting a Mitsubishi controls- Press system hard key then press parameters, press setup softkey, answer yes to question then select the soft keys such as base (1000's par. Any Help please. Press the softkey "PARAM". yes, that's what I'm currently doing. Aug 27, 2021 · Just manual jogging the robot. If little Johnny can't keep from messing around with machine parameters then perhaps little Jonny needs a stint on unemployment. There’s even a special “null” value that says the variable never had a value assigned. (3) To select the parameter screen, press the SYSTEM function key as many Re: Disable write protect key functionality. Sep 28, 2019 · Robotforum - Support and discussion community for industrial robots and cobots Dec 1, 2023 · Enter the correct axis number for the parameter to be queried (-1 = all axes, 0 = no axes, 1-n = axis number). May 13, 2016 · Parameter for Key protecting Tool Offsets. Jun 28, 2020 · Of course I figured it out after asking twice. Press the SERVICE soft key. That is an intelligent method. Convenient method 1) To change parameters in bit unit, press cursor key or , then the cursor becomes bit length and you can set parameters bit by bit (Bit parameter only). May need to page up or down to get to the top of the Parameter numbers. 1 and then Z -325. 233 DEVICE BUSY When an attempt was made to use a unit such as that connected via the RS–232–C interface, other users were using it. 09-17-2015, 04:14 AM #9. go to offsets and cursor over to the tool number and enter length, but I get "write protect". ;6 An attempt was made to reset bit 4 of parameter 3202 (NE9) or change parameter 3210 (PSSWD) when they are protected by a password. After a bit I was able to discover that besides the regular J4 and J5(I belive) that cause singularity. B–63690EN/01 Table of Contents c–1 Jun 13, 2006 · When I try to edit 3202#4 (ne9) to unlock the 9000s I get an alarm saying "write protected" This is with PWE enabled. 3401 Calculator Type Decimal Point or Integer. 1: protected. as the "Default Gateway-address" address. this happens for both tool and work offsets. Back up your ladder and go into the BOOT mode and delete the ladder file, then your controller will BOOT without the ladder so IF the ladder is doing it you will be able to change the date. 1 Z-325. Mar 10, 2023 · Fanuc. Mar 22, 2018 · warning message “WRITE PROTECTED” is displayed to indicate that the password cannot be modified. sinha_nsit. Bridgeport VMC3020. Press the SETTING function key until the "SETTING (HANDY)" page is displayed. 1?99) #2201-#2400 #10001?#10400 #11001?#11999 #12001?#12999 Jul 20, 2018 · Write protecting a program is pretty simple. 0: not protected. The control will enter an alarm state, this is normal. May 13, 2018 · Look for a board number on the edge somewhere. Im trying to get to open my door while my programm is running to save time, I presently just unscrew the lock on top, but would like to know what to do and where to go to set the door parameters. I looked at the parameters and they seem awfully large, but may not be when I consider the machine is in inches and there's a four place decimal. When I try to delete the macro it says cannot change system level macros G55 Select X type X0. Alarm is activated (Parameter "write enable" switch on) Param button. On the Select Screen, highlight the program you want to protect, then use the function key to enter its configuration settings (i can not remember exactly what the button says, but there are only a few options). I have found thet I need to modify Parameter 8000 - PWE to 1 to clear the write protect but have been unable to do so. Any Ideas? Apr 10, 2010 · On the Fanuc OM series control, You need parameter #0010 bit #4 to be a 0 to edit 9000's programs and 1 to protect the programs. Fanuc Password Hwacheon. find where you want zero on workpiece 3. Any change in work offsets would be overwritten with the original values. 13. When I try to enable parameter write it briefly changes to 1 then goes straight back to 0. Every time I try to copy ME get a Writer Protect popping above. Any help is appreciated, Thanks! We have 1 Fanuc 15 Parameter Manual for free PDF download. IIRC the only way to stop editing of programs is by the protect key on the front of the control. Page 2Overview By using this function, the “Enable” or “Disable” setting of “Parameter write” can be set by the signal. Yasnac- LX1 to LX3, MX1 to MX3 control- Change rotary switch by tape reader from 0 to 1, or parameter 6219. 3) ENTER 8000. Pressing RESET at power up only clears out the Parameters and Offsets. The parameter manual explains this. I just recently had to clear the memory on our Hardinge Cobra 42 because of a corrupted display. my CNC mill machine lock message came on since the beginning of this month, and I am totally unable to operate it any more. Also in Parameter 8134 set bit #2 Two ranges of part program numbers can be inhibited from editing by setting Pro 3 control parameter 3202. Jan 2, 2024 · For example, we can write “#1 = 100” to assign the value “100” to the variable “#1”. anyhelp would be greatly apreciated. 2. Position the cursor on "PARAMETER WRITE" field. go to MACHINE values and record eg X845. When an attempt is made to modify the password with G10 (programmable parameter input), P/S alarm No. I HAVE FOLLOWED THESE INSTRUCTIONS AND STILL CANNOT TURN ON PWE. from the keyword set in parameter No. I believe it is a password issue only. Locate parameter 8000. Aug 19, 2014 · Re: Fanuc Series 180i-MB : Program is Now Write ProtectedCannot Edit! If you're program is stored somewhere in between O8000 and O9999, parameter 3202 is used to edit-protect them ( perhaps someone changed the program number or the parameter ) 3202 bit 0 disable editing for program between O8000 and O8999. I thought to bring back the date to a date earlier than the date it brought this message into Fanuc 21-T programs are write protected. After the parameters have been input, set PARAMETER WRITE on the SETTING screen to 0. Jul 18, 2018 · write protect in macro input. Fanuc Macro System Variable lists parametric programming Purpose Variable number Contents Series Variable number #1000?#1015 #1032 #1100?#1115 #1132 #1133 #2001?#2064 #10001-#10999 #11001-#11999 #2001-#2200 (Offset No. There can be a hardware method inside the control, as in a PC. Parameter 3202. 3----> 1 fanuc 31i controller. OUTPUTTING (2) To select the parameter screen, press the SYSTEM function key as PARAMETERS many times as required, or alternatively press the SYSTEM functio. <PROG>, and only the program being edited will be deleted. Select MDI mode. 3----> 1 fanuc 31i controller Oct 15, 2015 · Hi, Does anyone know the exact method of enabling parameter protection on Fanuc controller systems so that a person wont be able to change the parameters just by enabling the parameter write enable key in the Setting screen ? Thanks a Lot in advance :) Jan 20, 2022 · What we do when we are setting ( G54 to G59) is enter this position in the work offset page. Aug 20, 2018 · I'm having an issue trying to copy a . Set mode to MDI, Set PWE to 1, change the parameters then after you have finished, power the machine off then on. 4) PRESS SOFTWARE KEY 'INP-NO',THEN DATA NUMBER 8000 PARAMETER. I am trying to change the jog speed for a r-30ib plus robot. This is my first time posting on this forum, but I am very familiar with Fanuc controls. Enabling parameter write is so simple and basic that I personally am suspect of anyone who want to poke around inside the parameters un-supervised. Dear all. Ask some Fanuc service guy. Thousands of CNC Programming, Operating & Maintenance Manuals Re: write protect in macro input. Type "10000001" and press "INPUT". About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright Jul 13, 2022 · I have a home_io macro that I want to change or delete. At the same time an alarm condition (P/S100 PARAMETER WRITE ENABLE) occurs in the NC. Aug 30, 2021 · Correct the program. I'm positive that the MEASURE button was used the day before, amd worked. Mar 28, 2023 · I now have parameter backup and i have succesfully passed the normal parameters via the rs232 port. Find out the values stored in G54 etc and insert the suggested lines in the beginning of the program. I didn't say 100% without a doubt it was PWE, but 99% of the time when I get a Write Protect alarm, I turn on PWE and it goes away; the rest of the time it's generally program protection enabled. These programs along with 8000 to 8999 can be locked so no one can mess with them. . Press the function Hard key "SYSTEM". You might have to try jogging and see if any of those bits turn on. 100 - PARAMETER WRITE ENABLE. Re: help with fanuc 18i mb pmc data (pages) go to system Diagnostic and see if any of those bits are on. . page down, cursor down to #0901. 01-15-2011, 07:09 PM #8. It is really your preference. 1?49) Wear offset value (Offset No. PWE=1 Memory Switch: the machine doesn't have one, allowed me to write normal parameters (maybe it is unlocked) but won't let me write a program (maybe it is locked). [Data type] 2–word axis. I really think it is something the other company did to it. LS file from UT1: to MD: and getting 'Device is protected'. Always backup parameters before making any changes. Jun 14, 2010 · Parameter write enabling on Fanuc OiT. 5 in Y. 2 enter into work page and enter the coordinates say G55 X845. One parameter represents the value of the first permanent common variable to protect (setting this parameter to 500 will protect from #500). 6005 Allows the Use of Local Subroutines (Newer Control) 6050-6059 Allows you to Call a 9000 series Program with a G Code. If I try to change the program I get a memory protection violation. ro cp gp bb mw hv gb sj tl gp